plastic gas pipe bonding in moldova

Bonding and grounding on gas line - InspectionNews

Mar 31, 2012· The gas line is already bonded to the eletrical system by the EGC in the appliance(s) it''s connect to. When you plug in a gas stove to a wall receptacle the gas pipe is connected to metal frame of the stove which is grounded so adding an additional bonding …

Grounding and Bonding of Gas Piping | Electrical …

Judging by the responses to NECA’s online “Code Question of the Day (CQD),” gas piping and its use in bonding and grounding sure generated controversy and explosive comentary. The following questions and answers should clarify what many readers are asking.

IET Forums - Main gas bonding -apparently we are all …

15/6/2010· IET Onsite Guide page 45. "4.5 Main protective bonding of plastic services. There is no requirement to bond an incoming service where the service pipe is plastic, for example, where yellow is used for natural gas and blue for potable water. Where there is a plastic

Polyethylene - Wikipedia

Polyethylene burns slowly with a blue flame having a yellow tip and gives off an odour of paraffin (similar to candle flame). The material continues burning on removal of the flame source and produces a drip. Polyethylene cannot be imprinted or bonded with adhesives without pretreatment.

Grounding vs Bonding - Part 10 of 12 | Electrical

Size this bonding jumper per Table 250.122, based on the ampere rating of the occupancy feeder overcurrent protection device. Other metal piping systems. You must bond metal piping systems (such as gas or air) to an effective ground-fault current path, if they''re likely to become energized [250.104(B)].

Installation Guide - Peoples Gas

Note: As of March 6, 2015, medium-density (yellow) polyethylene plastic pipe over three years old and/or high-density (black) polyethylene plastic pipe over ten years old from date of manufacture, is not suitable for use in the Peoples’ pipeline system.

How to fuse polyethylene butt joints together? [with graphics]

I am trying to fuse polyethylene butt joints together. So far I have only found one method that is pretty impractical for my purpose. Welding them together with plastic rod, seems to heat the poly too much and causes warpage. My question to you is, Is there anything that will bond polyethylene together.

Bonding for gas meter | Screwfix Community Forum

7/10/2016· The new gas pipe may be plastic MDPE, but that will only run to the meter. The gas pipe from the meter into the house will be done by your gas safe pluer, and this will be run in copper. So you''ll need to bond the copper pipe where it enters the garage.

CSST Flexible Gas Pipe - HOME-FLEX

qualified sources. Additional information on gas piping systems is available from your local gas utility or propane supplier. General usage guidelines of HOME-FLEX® flexible gas piping are outlined as follows: The piping system is for use with fuel gases only and is intended for operating pressures not exceeding 25 PSI (172.5 kPa).

Bonding gas meter. | DIYnot Forums

21/3/2018· I have just had a smart meter installed and the engineer pointed out that the gas meter is not earthed. The gas supply by the way is by a heavy gauge steel pipe to the No, you must connect the gas pipe as near as practicable to its point of entry to the premises to …

Grounding and Bonding Against Static Electricity

Grounding and Bonding Against Static Electricity Jon Koppari, CSP, MS Occupational Safety and Health Instructor . Connectors for bonding and grounding, such as copper wire and – Plastic pipes – Gas or steam pipes – Dry pipe sprinkler systems – Lightning rods

Butt-fusion jointing of polyethylene (PE) pipes -

Mar 19, 2012· This videos demonstrates the butt-fusion welding procedure for polyethylene (PE) pipes. For butt-fusion jointing of Protecta-Line and Secura-Line pipes…

Bonding and Grounding of Flammable Liquids - Quick Tips

For bonding and grounding to be effective, a metal-to-metal connection must be maintained between the bonding and grounding wires and the containers. To accomplish this, all paint, dirt, rust, etc. must be removed from the area of connection. These connections …

Tips for Gluing a Polyethylene Pipe | DoItYourself

When you are fitting in some polyethylene pipe, whether it is for water supply, drains, or for gas, you need to make sure that you have glued it securely.This type of pipe requires that you use a specialist type of glue in order to hold the pieces tightly for longer.

CSST Safety - Frequently Asked Questions

ANSWER: If you have CSST in your home or business you should determine if the fuel gas piping system is bonded and grounded. This requirement will include the attachment of a listed bonding clamp (click for picture) and bonding wire to the gas piping system.

Bonding and grounding on gas line - Home Inspection

Mar 31, 2012· The gas line is already bonded to the eletrical system by the EGC in the appliance(s) it''s connect to. When you plug in a gas stove to a wall receptacle the gas pipe is connected to metal frame of the stove which is grounded so adding an additional bonding …

Bonding Water Piping: Is It A Metal System or Not

At what point does the water piping system no longer provide a good electrode reference point? It’s where the water pipe does not have a direct metal-to-earth connection for 10 feet or more. A predominantly nonmetallic piping system is unlikely to have 10 feet of metal pipe …

Which Epoxy is Best for Plastic? Let''s find out! -

24/8/2017· I''ve had hundreds of comments requesting I create a video testing which epoxy is best for plastic. Are epoxies designed for plastic as good as those designed for general purpose? Which name brand is best? In this video, I use 3 tests to determine which epoxy is

Must-Know Facts About Your Piping System

Jan 24, 2018· Direct bonding on your natural gas system reduces the chances of electrical shock, as well as a natural gas leak or fire. 3. CSST piping can be damaged by lightning. Lightning striking a CSST gas line system can be extremely dangerous. A strike on or near a building can travel through the structure’s piping system and cause a damaging power

Grounding & Bonding — Why it is done And How to Install

• If metal underground water pipe is used as the sole grounding electrode system, according to 250.53(D)(2) of the Code, it has to be supplemented with other grounding electrodes as listed in this section. The reason for this is based on the possibility of using a plastic water pipe in the future when the original metal water

What are the CSST gas line requirements? | Blue Palmetto

It is thought that the proper installation and bonding of this piping system makes it a safe alternative to black pipe. Millions of homes have csst installed in them. CSST typically has a yellow pvc or polyethylene outer jacket which mainly serves to protect the …

Types of Flexible Gas Lines | eHow

Available in up to 500-foot lengths and iron and copper pipe size diameters, polyethylene (PE) gas pipe is used to bring natural gas or LP gas to a building. It is made of medium-to-high-density polyethylene, which is a noncorrosive, durable and relatively inexpensive plastic compound. PE gas line is used for exterior underground installation only.

Butt Fusion Joining Procedure and - Engineered Pipe Group

When used to join Uponor Infra polyethylene gas pipe and fittings, Uponor Infra fusion joining procedures are qualified in accordance with U.S. Department of Transportation Regulations. • D.O.T. Regulations require that each joint in a gas piping system must be made in accordance with written

Effective Grounding/Bonding for Fire Prevention

Effective Grounding/Bonding for Fire Prevention Ground all containers for extra safety In the handling of containers of flammable liquids having high electrical resistance and low flash points, possible loss of life, loss of property and interruption to business can be greatly minimized by effective grounding and bonding of the containers.

Bonding and grounding of plastic containers during

In particular, you want to know OSHA''s position on the bonding and grounding of plastic containers during the dispensing or transferring of Class I flammable liquids. The requirements for bonding and grounding of containers during the transfer of Class I flammable liquids are contained in 29 CFR 1910, paragraph (e)(6)(ii).

Electrical Bonding of Gas Piping Systems | American Gas …

This American Gas Association fact sheet provides an overview of the requirements for the electrical bonding of fuel gas piping systems to the electrical grounding system based on ANSI Z223.1/NFPA 54, National Fuel Gas Code - 2018 (NFGC). The bonding